![]() NOTE: IF THE BLOWER IS STILL RUNNING AND THE RED AND BLUE LED's ARE NOT ALTERNATELY FLASHING, GO BACK TO STEP 1. After you have successfully turned on only those 5 switches, the blower should turn OFF and the RED and BLUE LED's should be alternately flashing. Step 3. Turn ON the following configuration switches. Step 2. Turn ALL the configuration switches on the Qwik Swap ® V3 board to OFF. ![]() Step 1. Be sure the Qwik Swap ® V3 is powered up and the unit's blower is running when it shouldn't be running. Instructions for setting the Input Mask are shown in Appendix A1 (Adjusting the Input Configuration for ECM 2.0 & 2.3 motors only) in your instruction sheet. The Qwik Swap ® V3 board must be told which commands to ignore, and this is done by setting the Input Mask, which tells the Qwik Swap ® board the commands to ignore. For example, while the thermostat may not be calling for cooling, a humidistat may be commanding the blower to operate. Sometimes there may be multiple commands telling the blower to operate. Specifications Qwik Swap ™ X1 Motor Voltage Once the humidity drops to below 50%, the control board returns to optimizing performance. When installed on the control board and the relative humidity in the return air is measured to be greater than 50%, the control board control logic changes from maximizing performance to maximizing moisture removal. While Qwik Swap X3, Qwik Swap V3 and our Qwik SEER+ WattSaver all provide variable blower air flow leading to improved humidity removal, if humidly remains an issue these control boards have a simple plug-in connection for this optional humidly sensor. View the product data sheet and instructions for this adapter HERE. Useful for replacing ECM 2.3 or Eon Motors in fan coil units to Evergreen® CM or EM motors. As with any Qwik Swap, installation simply requires moving wires from the failed ECM motor to the Qwik Swap V3 board, then connecting the new PSC motor’s common and the three power leads (one for each speed) to the Qwik Swap V3 board (along with a capacitor). 2.3, 2.5 or 3.0 motor with a Permanent Split Capacitor (PSC) motor while maintaining variable blower air flow capability. Provides replacement of a failed OEM Variable Air Flow Rate ECM 2.0. Installation is as simple as moving the wires from the failed ECM motor to the Qwik Swap X3 board, then connecting the replacement PSC motor’s common and three power leads (one for each speed) to the Qwik Swap X3 board (along with a capacitor). Provides replacement of a failed OEM Constant Torque ECM, X13 ® or SelecTech ® motor with Permanent Split Capacitor (PSC) motor while also ADDING performance improving variable blower air flow capability - like high end systems have. ![]() Installation is as easy as moving wires from the failed ECM motor to the Qwik Swap X1 board, then connecting the replacement PSC motor’s common and power lead to the Qwik Swap X1 board (along with a capacitor). The basic Qwik Swap X1 (QT6101) provides a single technician-selected motor speed when replacing a failed OEM Constant Torque ECM, X13® or SelecTech® motor. Qwik Swap boards operate with any PSC motor up to 1 horsepower, either 120 or 240 VAC single phase. There is a Qwik Swap board for every type of ECM motor.Īnd it is a solution you can have on the truck, with no custom programming required. Qwik Swap is a money saving solution that allows the replacement of a failed OEM ECM, X13® or SelecTech® Motor with a lower cost, more reliable, Permanent Split Capacitor (PSC) motor, along with a capacitor. Now you can have the solution on the truck and save money too. It is impractical to have all the different variations of ECM motors on the truck, so a failed ECM blower motor typically means a trip to the parts house and a few hours wasted. The Low-Cost, Robust Alternative to Expensive Unreliable ECM Motors Both the Qwik Swap X3 and V3 work with optional Humidity Sensor (QT6001) for enhanced humidity removal.Equipped with 6,000 Amp, 100 Joules surge protection on all high voltage circuits.Both the Qwik Swap X3 and V3 provide improved humidity removal compared to fixed-speed operation (56 % improvement at 82☏, 157% at 97☏ outdoor air temperature).Both the Qwik Swap X3 and V3 automatically select the optimum PSC motor blower speed (Low, Medium or High) every time the unit cycles on.Fast Replacement, without programming simply transfer the connection from the ECM motor to the Qwik Swap Board and wire the Qwik Swap board to any PSC motor.Provides Variable Blower Air Flow (except the X1, QT6101).The solution is on your truck – No need to wait and pay for that expensive OEM motor replacement.Direct replacement for any Constant Torque or Variable Air Flow ECM motor up to 1 HP.Qwik Swap ® The ECM Motor Change-Out Solution. REPLACES COMMUNICATING MOTORS (Emerson®, Nidec®, US Motors®) REPLACESx CONSTANT TORQUE ECM (X13) MOTORS UP TO 1 HP
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |